Page view 38
OM-4409 Page 35
6-4. Using Remote Voltage/Amperage Control
1 Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 5-10).
0774 / Ref. 217 356-A / 803 231
Example: Combination Remote Amperage Control (Stick)
In Example:
Process = Stick (Using Remote On/Off)
Range = 125 to 400 A DC
Min = 125 A DC
Max = 400 A DC
Adjust Optional Remote Control
Set
Panel/Remote
Switch
Set Range Control Not Used
In Remote On/Off
Switch Required
Stick Mode
Max (400 A DC)
Min (125 A DC)
Set Remote
Process
Example: Combination Remote Amperage Control (TIG)
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 330 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 185 A DC (50% of 40 to 330)
Adjust Optional Remote Control
Set Range
Set Control
Max (185 A DC)
Min (40 A DC)
Set Remote
Process
1
803 231
Set
Panel/Remote
Switch
Page view 38