Miller Electric 230Volt Owner's Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
OM-263 001 Page 25
6-2. Controls And Components
1 Controller Interface
See Sections 6-3 thru 6-9 for controller
programming information.
2 Power Switch
Turn switch to the On position to supply
power to the fume extractor.
3 Start Button
4 Stop Button
Press Start button to turn fan blower on.
Press Stop button to turn fan blower off.
5 Remote Control Switch
Rotate switch to the Panel position to use
front panel controls to turn fan blower on
and off. Rotate switch to the Remote posi-
tion to turn fan blower on and off from a re-
mote location or with a peripheral device.
To Start
Rotate Power switch to the On position.
Press Start button.
To Stop
Press Stop button. Rotate Power switch
to the Off position.
6 Damper Control
NOTICE Excess airflow can shorten fil-
ter life and cause electrical system and
blower motor failure.
When replacing filters, reset the
damper to the fully-closed position
and then open the damper to reestab-
lish desired airflow.
The exhaust damper can be adjusted to
regulate or limit airflow when unit is in op-
eration. Before start-up, set the exhaust
damper to the fully-closed position. Ad-
justments to airflow can be made by
loosening the wing nut and sliding the
handle to open or close the damper.
7 Collection Bin
See Section 7-3 for information on empty-
ing particles from the collection bin.
1
6
7
2
5
3
4
LOCAL
OFF
REMOTE
254 231-B / 252 992
Page view 28
1 ... 28 29 30 ... 106

Comments to this Manuals

No comments