4-7.
Selecting
Weld
Cable
Sizes
Welding
Amperes
Total
Cable
(Copper)
Length
In
Weld
Circuit
Not
Exceeding
100
ft
(30
m)
Or
Less
150ft
I
200ft
I
250ft
I
300ft
I
350ft
I
400ft
(45
m)
I
(60
m)
I
(70
m)
I
(90
m)
I
(105
m)
I
(120
m)
I
I I
I
10
60%
Duty
Cycle
60100%
Duty
Cycle
10
100%
Duty
Cycle
100
4 4
4 3 2
1
1/0
1/0
150
3 3
2
1
1/0
2/0
3/0
3/0
200
3
2
1
1/0
2/0
3/0
4/0
4/0
250
2
1
1/0
2/0
3/0
4/0
2-2/0
2-2/0
300
1
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
350
1/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
400
1/0
2/0 3/0
4/0
2-210
2-3/0
2-4/0
2-4/0
500
2/0 3/0
4/0
2-2/0
2-3/0 2-4/0
3-3/0
3-3/0
Weld
cable
size
(AWG)
is
based
on
either
a
4
volts
or
less
drop
or
a
current
density
of
at
least
300
circular
mils
per
ampere.
Contact
your
distributor
for
the
mm2
equivalent
weld
cable
sizes.
S-000l-E
OM-173
413
Page
21