OM-499 Page 24
Return To Table Of Contents
7-4. Wiring Instructions For Optional 120/240 Volt Twistlock Plug (NEMA L14-30P)
plug3-11/99 − 802 527
1 Plug Wired For 120/240 V,
3-Wire Load
When wired for 120 V loads, each du-
plex receptacle shares a load with
one half of the 240 V receptacle.
2 Neutral (Silver) Terminal
3 Load 1 (Brass) Terminal
4 Load 2 (Brass) Terminal
5 Ground (Green) Terminal
6 Cord Grip
Strip cord jacket back enough to sep-
arate conductors.
Strip conductors enough to make
good contact with plug terminals.
Make plug connections and reinstall
outer shell and cord grip.
Tighten assembly screws onto shell.
Do not overtighten.
1
3
2
4
Tools Needed:
5
6
120 V
240 V
120V
SECTION 8 − MAINTENANCE
Follow the storage procedure in the engine owner’s manual if the unit will not be
used for an extended period.
NOTE
8-1. Maintenance Label
Ref. S-175 679-A
ENGINE MAINTENANCE
8 h
1.1 l (1.2 US qt,
1.94 lmp qt)
Unleaded
86 + Octane
6.5 l (1.7 US Gal,
11.4 lmp pt)
50 h
100 h
10W-30
°F
+32
+59
+86+30
+20
+10
0
+40
°C
+104
-10
-10
-15
-20
200 h
0.7 − 0.8 mm
(0.028 − 0.031 in)
SG-SF/CC-CD