OM-220 340 Page 13
SECTION 4 − SPECIFICATIONS AND INSTALLATION
4-1. Serial Number And Rating Label Location
The serial number and rating information is located on the bottom of the machine. Use the rating labels to determine input power requirements and/or
rated output. CE model rating labels will also display the following symbols: CE, CCC, WEEE, and IEC 60974-1. For future reference, write serial
number in space provided on back cover of this manual.
4-2. Specifications
Input Power
Single-Phase
AC
Rated Welding
Output
Welding
Amperage
Range
Max
OCV
DC
Amperes In-
put At Rated
Load Output,
50/60Hz,
Single-Phase
KVA @
Duty
Cycle
KW Dimensions Weight
115 Volts Stick
70A @ 22.8 Volts DC,
100% Duty Cycle
20 − 100A
69V
*12-16
17.4 2.0 1.9
H: 9 in (229 mm)
W: 5.5 in (140 mm)
L: 13.25 in (337 mm)
13.7 lb
(6.2 kg)
100A @ 24.0 Volts DC,
35% Duty Cycle
26.4 3.0 3.0
115 Volts TIG
100A @ 14.0 Volts DC,
100% Duty Cycle
5 − 150A
69V
*12-16
18.4 2.1 2.1
150A @ 16.0 Volts DC,
30% Duty Cycle
28.0 3.4 3.1
230 Volts Stick
100A @ 24 Volts DC,
100% Duty Cycle
20 − 150A
69V
*12-16
13.1 3.0 2.8
150A @ 26.0 Volts DC,
30% Duty Cycle
21.6 4.9 4.7
230 Volts TIG
100A @ 14.0 Volts DC,
100% Duty Cycle
5 − 150A
69V
*12-16
8.3 2.0 1.9
150A @ 16.0 Volts DC,
30% Duty Cycle
14.2 3.2 3.1
*Sense Voltage For Stick And TIG Lift Arc
4-3. Duty Cycle And Overheating
208 608-C
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, the
Overtemperature Light comes On,
and the cooling fan runs. Wait fif-
teen minutes for unit to cool. Re-
duce amperage or duty cycle be-
fore starting to weld again.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
% Duty Cycle
Output Amperes
10
100
0
50
100
150
200
250
Stick (230V)
Stick (115V)
TIG (115 &230V)