OM-225 757 Page 11
SECTION 3 − INSTALLATION
3-1. Specifications
Rated Welding
Output
Amperage/Voltage
Range
Max OCV−DC
Amperes Input at Rated Load Output 60 Hz,
Single-Phase
200 V 230 V 460 V 575 V KVA KW
275 A @ 31 Volts
DC, 50% Duty
Cycle
5 − 400A In CC
Mode
85 VDC In
CC Mode
66
*1.66
57
*1.66
29
*0.83
23
*0.66
13
*0.66
11.2
*0.2610 − 35V In CV
Mode
85 VDC In
CV Mode
*While idling
3-2. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
Overheating
0
15
A/V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 / 225 765-A
5 Minutes Welding 5 Minutes Resting
50%dutycycle
Comments to this Manuals