Miller Electric MOG-400AC Specifications Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
OM-202 137 Page 19
4-9. Remote 14 Receptacle Information
ST-801 192
AJ
B
K
I
C
L
NH
D
M
G
E
F
Socket* Socket Information
24 VOLTS AC
A 24 volts AC. Protected by supplementary protect-
or CB2.
B Contact closure to A completes 24 volts AC con-
tactor control circuit.
115 VOLTS AC
I 115 volts AC. Protected by supplementary pro-
tector CB1.
J Contact closure to I completes 115 volts AC con-
tactor control circuit.
REMOTE
OUTPUT
CONTROL
C Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D Remote control circuit common.
E 0 to +10 volts DC input command signal from re-
mote control.
A/V
AMPERAGE
VOLTAGE
H Voltage feedback; +1 volt DC per 10 output recep-
tacle volts.
F Current feedback; +1 volt DC per 100 amperes.
M CC/CV select
GND
G Circuit common for 24 and 115 volts AC circuits.
K Chassis common.
*The remaining sockets are not used.