Miller Electric XMT 350 CC/CV Owner's Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
OM-233 865 Page 15
4-5. Remote 14 Receptacle Information
AJ
B
K
I
C
L
NH
D
M
G
E
F
Socket* Socket Information
24 VOLTS AC
A 24 volts AC. Protected by circuit breaker CB2.
B Contact closure to A completes 24 volts AC
contactor control circuit.
115 VOLTS AC
I 115 volts AC. Protected by circuit breaker CB1.
J Contact closure to I completes 115 volts AC
contactor control circuit.
REMOTE
OUTPUT
CONTROL
C Output to remote control; 0 to +10 volts DC, +10
volts DC in MIG mode.
D Remote control circuit common.
E 0 to +10 volts DC input command signal from
remote control.
M CC/CV select
A/V
AMPERAGE
VOLTAGE
F Current feedback; +1 volt DC per 100 weld am-
peres.
H Voltage feedback; +1 volt DC per 10 weld volts.
GND
G Circuit common for 24 and 115 volts AC circuits.
K Chassis common.
*The remaining sockets are not used.
Ref. 803 879-B
1 115 V 10 Amp. AC
Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 4-5).
2 Circuit Breaker CB1
3 Circuit Breaker CB2
CB1 protects duplex receptacle
and 115 volts AC portion of Remote
14 receptacle from overload.
CB2 protects 24 volts AC portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2 3
1
4-6. 115 Volts AC Duplex Receptacle And Circuit Breakers