OM-229 253 Page 24
4-12. Remote 14 Receptacle And Terminal Strip 1T Information
Socket Terminal Information
24 VOLTS AC
A A 24 volts AC. Protected by circuit breaker CB2.
B B Contact closure to A completes 24 volts AC contactor control circuit.
REMOTE OUTPUT CONTROL
C C Command reference; 0 to +10 volts DC (CC), +10 volts DC (CV).
D D Remote control circuit common.
E E 0 to +10 volts DC input command signal from remote control.
F * Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
H * Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
115 VOLTS AC
I I 115 volts, 15 amperes, 60 Hz DC. Protected by circuit breaker CB1.
J J Contact closure to I completes 115 volts AC contactor control circuit.
GND
K
G
K
*
Chassis common.
Circuit common for 24 and 115 volts AC circuits.
REMOTE POWER ON/OFF
* L
To remote On/Off switch.
* M
REMOTE VOLTAGE SENSING
N N Voltage sensing signal from Negative (−) weld output terminal.
* P Voltage sensing signal from Positive (+) weld output terminal.
* Not Used