Visit our website atwww.MillerWelds.comProcessesDescriptionStick (SMAW) WeldingOM-220 812BMarch 2005Arc Welding Power SourceTIG (GTAW) WeldingCST 250
OM-220 812 Page 6Le rayonnement de l’arc génère des rayons visibles etinvisibles intenses (ultraviolets et infrarouges) suscep-tibles de causer des br
OM-220 812 Page 72-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien del’appareil.Risque D’INCENDIE OU D’EXPLO-SION Ne
OM-220 812 Page 82-4. Principales normes de sécuritéSafety in Welding, Cutting, and Allied Processes, norme ANSI Z49.1,de l’American Welding Society,
OM-220 812 Page 9SECTION 3 − INSTALLATION3-1. SpecificationsWeldingModeInputPowerRatedOutputWeldingAmperageRangeMaximumOpen-CircuitVoltageAmperes Inpu
OM-220 812 Page 103-3. Stick (SMAW) Volt-Ampere CurvesVolt-ampere curves show minimumand maximum voltage andamperage output capabilities ofwelding pow
OM-220 812 Page 113-4. TIG (GTAW) Volt-Ampere CurveVolt-ampere curves show minimumand maximum voltage andamperage output capabilities ofwelding power
OM-220 812 Page 123-5. Selecting A Location1 Line Disconnect DeviceLocate unit near correct inputpower supply. Special installation may berequired wh
OM-220 812 Page 133-6. Weld Output Terminals And Selecting Cable Sizes*Weld Cable Size** and Total Cable (Copper) Length in Weld CircuitNot Exceeding1
OM-220 812 Page 143-7. TIG Lift-Arct DCEN (Direct Current Electrode Negative) ConnectionsRef. 802 888 / Ref. 803 0801 Positive (+) Weld OutputTerminal
OM-220 812 Page 153-8. Stick DCEP (Direct Current Electrode Positive) ConnectionsRef. 802 888 / Ref. 803 0801 Negative (−) Weld OutputTerminalConnect
Miller Electric manufactures a full lineof welders and welding related equipment.For information on other quality Millerproducts, contact your local M
OM-220 812 Page 163-10. Selecting 220 Volts AC Single/Three Phase Input Voltage803 079 / 803 077 Turn Off welding powersource, and disconnectinput po
OM-220 812 Page 173-11. Selecting 400 - 440 Volts AC Three Phase Input Voltage803 079 / 803 078 Turn Off welding powersource, and disconnectinput pow
OM-220 812 Page 18 Disconnect and lockout/tag-out input power beforeconnecting input conduc-tors from unit. Have only qualified personsmake this ins
OM-220 812 Page 19SECTION 4 − OPERATION4-1. Controls220 685-A / 803 080NOTE: Green on nameplate indicates a TIGfunction, Gray indicates a Stick functi
OM-220 812 Page 204-2. Process Select Control1 Process Select ControlRotate knob to select desiredprocess.Lift-Arc TIG - Normalopen-circuit voltage
OM-220 812 Page 214-3. Stick Start Procedure − Scratch Start TechniqueWith Stick selected, start arc asfollows:1 Electrode2 Workpiece3 ArcDrag electro
OM-220 812 Page 224-5. Amp Adjust Control1 AMP ADJUST (AmperageControl)Rotate knob clockwise to increaseamperage (5-250 amps).14-6. Remote 14 Receptac
OM-220 812 Page 23SECTION 5 − MAINTENANCE AND TROUBLESHOOTING5-1. Routine Maintenance Disconnect power before maintaining. Maintain more often durin
OM-220 812 Page 245-3. Troubleshooting121 Output LED (Blue)2 High Temperature LED(Yellow)803 080Trouble Possible Causes RemedyNo weld output; unit com
OM-220 812 Page 25Trouble RemedyPossible CausesErratic or improper weld output. Weld cable too small or defective. Use proper size and type of weld ca
TABLE OF CONTENTSSECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Us
OM-220 812 Page 26SECTION 6 − ELECTRICAL DIAGRAMSFigure 6-1. Circuit Diagram206 171-D
OM-220 812 Page 27SECTION 7 − SELECTING AND PREPARINGTUNGSTEN ELECTRODEgtaw 7/97For additional information, see your distributor for a handbook on the
OM-220 812 Page 287-3. Preparing Tungsten For AC Or DC Electrode Negative (DCEN) WeldingRef. S-0161 / Ref. S-01621 Tungsten Electrode2 Tapered EndGrin
OM-220 812 Page 29Notes
OM-220 812 Page 30SECTION 8 − PARTS LIST Hardware is common andnot available unless listed. 803 157-B812132021252372422324105196151914141518171928261
OM-220 812 Page 31DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 8-1. Main AssemblyQuantity1 205758 PANEL,FRONT W/CMPNT 1. . . . . . . . . . . . . . . .
OM-220 812 Page 32 Hardware is common andnot available unless listed. 803 158149131215317421811982046522211016117723Figure 8-2. Panel, Front w/Compon
OM-220 812 Page 33 Hardware is common andnot available unless listed. 803 161-B76127345Figure 8-3. Panel, Rear w/ComponentsDescriptionPartNo.Dia.Mkgs
OM-220 812 Page 34 Hardware is common andnot available unless listed. 803 163-B1331109111214878254681615Figure 8-4. Magnetics SubassemblyDescriptionP
OM-220 812 Page 35 Hardware is common andnot available unless listed. 803 159-C481967321213111012513Figure 8-5. Heat Sink Assembly, Output DiodeDescr
OM-220 812 Page 36 Hardware is common andnot available unless listed. 803 16023154876Figure 8-6. Base AssemblyDescriptionPartNo.Dia.Mkgs.ItemNo.Figur
OM-220 812 Page 37 Hardware is common andnot available unless listed. Ref. 803 162123Figure 8-7. Heat Sink Assembly, InputDescriptionPartNo.Dia.Mkgs.
Notes
Warranty Questions?Call1-800-4-A-MILLERfor your localMiller distributor.miller_warr 1/05Your distributor also givesyou ...ServiceYou always get the fa
PRINTED IN USA © 2005 Miller Electric Mfg. Co. 1/05Miller Electric Mfg. Co.An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914 US
OM-220 812 Page 1SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USINGsom _8/031-1. Symbol UsageMeans Warning! Watch Out! There are possible hazardswith
OM-220 812 Page 2Arc rays from the welding process produce intensevisible and invisible (ultraviolet and infrared) raysthat can burn eyes and skin. Sp
OM-220 812 Page 31-3. Additional Symbols For Installation, Operation, And MaintenanceFIRE OR EXPLOSION hazard. Do not install or place unit on, over,
OM-220 812 Page 41-5. Principal Safety StandardsSafety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,from American Welding Society, 5
OM-220 812 Page 5SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE AVANTUTILISATIONsom_fre 8/032-1. Signification des symbolesSignifie « Mise en garde. Faire
Comments to this Manuals