To select a generator that has enough power output in watts, add the watts for
the items you want to simultaneously run. Tools and appliances with induction
motors may require 37 times the listed wattage when starting. All data listed
is approximatecheck your tool/appliance for specific wattage requirements.
Bobcats will easily start and run the following equipment:
For example, if you’re welding at 125 amps you also have 5200 watts
available for powering lights or tools (either 43 amps from the 120 volt
full kVA receptacle or 21 amps from the 240 volt full kVA receptacle).
*50 A, 120/240 VAC receptacle. See Owner’s Manual for additional information.
TYPICAL EQUIPMENT POWER USAGE
Equipment Starting Watts Running Watts
Barn Cleaner (5 HP) 11,600 3000
Silo Unloader (5 HP) 12,200 4300
Portable Conveyor (1/2 HP) 3400 1000
Milker (5 HP) 10,500 2800
Hand Drill (1/2 inch) 600 600
Circular Saw (8-1/4 inch) 1400 1400
Air Compressor (1-1/2 HP) 8200 2200
Flood Lights (Vapor) 1250 1000
Refrigerator/Freezer 2200 700
Sump Pump 1300 800
Millermatic
®
212 Auto-Set
6500 6500
MIG Welder (230 V)
Spectrum
®
625 X-TREME
6900 6900
(30 A, 230 V, 1/2 in cut)
SIMULTANEOUS WELDING AND POWER
120 V Full kVA 240 V Full kVA
Weld Current Total Power Receptacle Receptacle
in Amperes in Watts Amperes Amperes
0 11,000 88* 44*
90 8000 66* 33
125 5200 43* 21
180 3500 29* 14
250 2200 18 9
The Bobcat Generator Power Advantage
Tools and motors are designed to operate within 10% of 120/240 VAC. The
Bobcat’s power generator provides strong power while keeping the voltage
within 10% of 120/240 VAC. This increases tool/motor performance and life.
GENERATOR POWER CURVE
0 10 20 30 40 50 60 70 80 90 100 110
0 20 40 60 80 100 120 140 160 180 200 220
AC POWER AMPS AT 120 V
0
25
50
75
100
108
125
150
0
50
100
150
200
216
132264
250
300
AC POWER VOLTS
AC POWER AMPS AT 240 V
Accu-Rated
Not Inflated Generator Power
Miller’s Accu-Rated
11,000 watts (12,000 with EFI) of
usable
peak power
is delivered for a minimum of 30 seconds. Accu-Rated means peak power
is usable for maximum generator loads such as plasma cutting,
Millermatic
®
MIG welders and motor starting. Accu-Rated peak power beats
the competition’s very short-duration peak or surge power. Use your peak
power, it’s more than a number.
Smooth PowerNot Spike Power
Revolutionary ten-degree skewed-rotor design
optimizes generator performance for smoother
powernot spiked power found with other
brands. Better powerbetter performance.
Waveform Comparison
Bobcat
Competitor
ENGINE
STATOR
1
3
2
Hot air
directed out
and upward
Cool air
in for
generator
Cool air in
for engine
Directed airflow improves cooling for long engine and component life.
All ratings are tested at 104˚F (40˚C)
to maintain tough work schedules, even
in hot weather.
Make deadlines, not excuses.
• 68% of service technicians, managers
and owners, recommend the Bobcat
over the competition.
• 98% of current owners are “satisfied
to very satisfied” with the Bobcat*.
*Based on an independent survey of
thousands of Bobcat owners.
Bobcat 68%
Others
Technician Recommendations
The Bobcat
Competitive
Advantage
The fully enclosed case design virtually eliminates hot air
recirculation when machine is mounted in tight spots.
Louver-directed air flow keeps the temperature of internal parts
cool for maximum performance and extended life.
Self-cooling stator barrel
completely encloses and protects
its generator from the dirtiest
and harshest environments.
1