OM-129 647 Page 21
5-2. Description Of Standard Controls (See Section 5-1)
This unit has a max OCV control circuit
that resets the Amperage/Voltage Con-
trol to maximum when the arc breaks.
When an arc is struck, weld output con-
trol returns to the front panel or remote
control setting. The Amperage/voltage
Control adjusts amperage only when
welding and does not adjust open-circuit
voltage.
1 Ampere Range Switch
Use switch to select one of five ampere
ranges.
For most welding applications, use lowest
amperage range possible to help prevent arc
outages.
Do not switch under load.
2 Amperage/Voltage Control
Control adjusts amperage within range se-
lected by Ampere Range switch. Weld output
would be 223 A DC with controls set as
shown (50% of 125 to 320 A).
3 Remote A/V Control Receptacle And
Switch
Connect optional remote control to RC3 (See
Section 4-9). Use switch to select front panel
or remote amperage control (see example
below).
4 Manual Stop Control
5 Engine Start Button
6 Ether Starting Aid Switch (Optional)
Push switch up and release while cranking
engine to release ether.
Do not use Ether if engine is running.
To Start: Press button and use Ether switch
(if necessary). Release button when engine
starts.
Do not crank engine while engine is turning.
To Stop: Pull control out and hold. Release
control when engine stops.
7 DC Ammeter (Optional)
8 DC Voltmeter (Optional)
9 Oil Pressure Warning Light
Light goes off if oil pressure is too low.
If light goes off, stop engine and
check oil level.
10 Battery Charging Warning Light
Light goes on when battery is not charging.
If light goes on, stop engine and
check engine belt.
11 Engine Hour Meter
12 Polarity Switch (Optional)
S-0774 / Ref. ST-180 933-B
Example: Combination Remote Amperage Control
In Example:
Range = 125 to 320 A
Percentage Of Range = 50%
Max = 223 A DC (50% of 125 to 320)
Adjust Optional Remote ControlSet Switches Set Range Set Percentage
Max (223 A DC)
Min (100 A DC)