2
Control Panels
Performance Data
1. Voltage Meter
2. High Temperature Shutdown Light
3. Amperage Meter
4. Power Switch with Indicator Light
Note: Weld output studs are energized by controls on the wirefeeder.
Turn off power before connecting remote device.
1. Voltage/Wire Speed Meter*
2. Voltage/Wire Speed Switch*
3. Remote Voltage Control Standard
4. Wire Speed Control
5. Jog/Purge Switch
6. Trigger Hold Switch
*Optional
Note: Power switch is on rear panel.
Rated Welding Output
375 A at 35 VDC,
100% Duty Cycle
Voltage Range DC
10–45
Amps Input at Rated Load Output, 60 Hz, Three-Phase
230 V 460 V 575 V KVA KW
69 34.5 27.5 27.5 17.5
4* 2* 1.6* 1.61* 0.46*
Dimensions
H: 30 in (762 mm)
(including lift eye)
W: 23 in (585 mm)
D: 30-1/2 in (775 mm)
(including strain relief)
Net
Weight
374 lb
(170 kg)
Delta-Fab Specifications (Subject to change without notice.)
24A Wire Feeder Specifications (Subject to change without notice.)
*While idling.