Miller-electric Big Blue 500 PT User Manual

Browse online or download User Manual for Tools Miller-electric Big Blue 500 PT. Miller Electric Big Blue 500 PT User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 90
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Processes
Description
TIG (GTAW) Welding
Stick (SMAW) Welding
MIG (GMAW) Welding
Engine Driven Welding Generator
OM-4429 2216 138H
200705
Visit our website at
www.MillerWelds.com
Flux Cored (FCAW) Welding
Air Carbon Arc (CAC-A)
Cutting and Gouging
File: Engine Drive
Big Blue 500 PT
Big Blue 600 X
(Perkins Turbo-Powered)
Page view 0
1 2 3 4 5 6 ... 89 90

Summary of Contents

Page 1 - Big Blue 600 X

ProcessesDescriptionTIG (GTAW) WeldingStick (SMAW) WeldingMIG (GMAW) WeldingEngine Driven Welding GeneratorOM-4429 2216 138H2007−05Visit our website a

Page 2 - From Miller to You

OM-4429 Page 6SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANTUTILISATIONrom_2007−04freSe protéger, ainsi que toute autre personne travaillant sur les

Page 3 - TABLE OF CONTENTS

OM-4429 Page 7DES PIÈCES CHAUDES peuventprovoquer des brûlures graves. Ne pas toucher à mains nues les parties chau-des. Prévoir une période de refr

Page 4

OM-4429 Page 8LES CHAMPS MAGNETIQUES peuv-ent affecter des implants médicaux. Porteur de simulateur cardiaque ou autre im-plants médicaux, rester à d

Page 5 - 1-2. Arc Welding Hazards

OM-4429 Page 9L’utilisation d’un groupe autonomeà l’intérieur PEUT VOUS TUER ENQUELQUES MINUTES. Les fumées d’un groupe autonome contient dumonoxyde

Page 6 - Medical Devices

OM-4429 Page 10LE SURCHAUFFEMENT peut endom-mager le moteur électrique. Arrêter ou déconnecter l’équipement avant dedémarrer ou d’arrêter le moteur.

Page 7 - 1-4. Compressed Air Hazards

OM-4429 Page 112-6. Proposition californienne 65 AvertissementsLes équipements de soudage et de coupage produisent desfumées et des gaz qui contiennen

Page 8

OM-4429 Page 12SECTION 3 − DEFINITIONS3-1. Warning Label Definitions (For Wordless Labels)3/961 Remove unit from shippingcrate. Remove Owner’sManual f

Page 9 - 1-8. EMF Information

OM-4429 Page 133-2. Manufacturer’s Rating LabelsCC Models CC/CV Models

Page 10 - UTILISATION

OM-4429 Page 143-3. Symbols And Definitions Some symbols are found only on CE products.Stop EngineFast (Run, Weld/Power)Slow (Idle) Start EngineStart

Page 11

OM-4429 Page 15SECTION 4 − SPECIFICATIONS4-1. Weld, Power, And Engine SpecificationsWeldingModeWeld OutputRangeRated WeldingOutputMaximumOpen-CircuitV

Page 12 - LE CARBURANT MOTEUR peut prov

Miller Electric manufactures a full lineof welders and welding related equipment.For information on other quality Millerproducts, contact your local M

Page 13

OM-4429 Page 164-3. Volt-Ampere Curves For CC Models203 412The volt-ampere curve shows theminimum and maximum voltageand amperage output capabilities

Page 14

OM-4429 Page 174-4. Volt-Ampere Curves For CC/CV Models217 811 / 203 415 / 217 810The volt-ampere curves show theminimum and maximum voltageand ampera

Page 15 - 2-8. Information EMF

OM-4429 Page 184-5. Fuel ConsumptionThe curve shows typical fuel useunder weld or power loads.215 082−AIDLEDC WELD AMPERES AT 100% DUTY CYCLEU.S. GAL.

Page 16 - SECTION 3 − DEFINITIONS

OM-4429 Page 194-7. AC Generator Power Curve193 018The ac power curve shows the gen-erator power in amperes availableat the 120 and 240 volt receptacl

Page 17 - CC Models CC/CV Models

OM-4429 Page 20SECTION 5 − INSTALLATIONinstall3 2007−04 − Ref. 800 652 / Ref. 800 477-A / 803 274 / 804 712! Always securely fasten weld-ing generator

Page 18 - 3-3. Symbols And Definitions

OM-4429 Page 215-2. Using Lifting EyeRef. 802 3111 Lifting Eye2 Nut3 Carriage BoltRaise lifting eye until it snaps inplace. Lower lifting eye when not

Page 19 - SECTION 4 − SPECIFICATIONS

OM-4429 Page 225-3. Mounting Welding GeneratorTools Needed:9/16 in224Welding Unit In PlaceBolting Unit In Place! Do not weld on base. Weld-ing on base

Page 20 - Work like a Pro!

OM-4429 Page 235-4. Installing Exhaust Pipe1/2 inTools Needed:Ref. 803 604 / Ref. 215 158! Stop engine and let cool. Point exhaust pipe in desired di

Page 21 - 217 811 / 203 415 / 217 810

OM-4429 Page 245-5. Activating The Dry Charge Battery (If Applicable)! Always wear a face shield,rubber gloves and protectiveclothing when working on

Page 22 - 4-5. Fuel Consumption

OM-4429 Page 255-7. Engine Prestart Checks Check all engine fluids daily.Engine must be cold and on a level surface.Unit is shipped with 20W break-in

Page 23 - 4-7. AC Generator Power Curve

TABLE OF CONTENTSSECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol

Page 24 - SECTION 5 − INSTALLATION

OM-4429 Page 265-8. Connecting To Weld Output Terminals803 602 / 803 778-ATools Needed:23/4 in1MIG and FCAW WeldingFor MIG and FCAW welding Direct Cur

Page 25

OM-4429 Page 275-9. Selecting Weld Cable Sizes*Weld Cable Size** and Total Cable (Copper) Length in Weld CircuitNot Exceeding***100 ft (30 m) or Less1

Page 26 - ! Do not weld on base. Weld

OM-4429 Page 285-11. Connecting To Remote 14 Receptacle RC14 On CC/CV ModelsSocket* Socket Information24 VOLTS ACA 24 volts ac. Protected by sup-pleme

Page 27

OM-4429 Page 29Notes

Page 28

OM-4429 Page 30SECTION 6 − OPERATING WELDING GENERATOR − CC MODELS6-1. Front Panel Controls For CC Models (See Section 6-2)12215 663 / 803 60211218131

Page 29 - 5-7. Engine Prestart Checks

OM-4429 Page 316-2. Description Of Front Panel Controls For CC Models (See Section 6-1)Engine Starting Controls1 Starting Aid SwitchUse switch to ener

Page 30 - ! Stop engine

OM-4429 Page 326-3. Remote Amperage Control On CC Models (Optional)1 Remote Amperage AdjustReceptacle RC13Connect optional remote control toRC13 (see

Page 32 - Welding Career Now!

OM-4429 Page 34SECTION 7 − OPERATING WELDING GENERATOR − CC/CV MODELS7-1. Front Panel Controls For CC/CV Models (See Section 7-2)215 664 / 802 60213OR

Page 33 - OM-4429 Page 29

OM-4429 Page 357-2. Description Of Front Panel Controls For CC/CV Models (See Section 7-1)Engine Starting Controls1 Starting Aid SwitchUse switch to e

Page 34 - 215 663 / 803 602

TABLE OF CONTENTSSECTION 7 − OPERATING WELDING GENERATOR − CC/CV MODELS 34 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1. Front Panel

Page 35

OM-4429 Page 367-3. Process/Contactor Switch On CC/CV Models1 Process/Contactor Switch! Weld output terminals are ener-gized when Process/Contactorswi

Page 36 - 212 944-B

OM-4429 Page 377-4. Remote Voltage/Amperage Control On CC/CV Models (Optional)1 Remote 14 Receptacle RC14Connect optional remote control toRC14 (see S

Page 37 - OM-4429 Page 33

OM-4429 Page 38SECTION 8 − OPERATING AUXILIARY EQUIPMENT8-1. 120 Volt And 240 Volt Receptacles191 624-A21 120 V 20 A AC GFCI Receptacle GFCI12 240 V 3

Page 38 - 215 664 / 802 602

OM-4429 Page 398-2. Connecting To Optional Three-Phase Generator (CC/CV Models Only)Ref. 197 399 / 802 332-E / 803 655 Place Process/Contactor switch

Page 39 - ! Electric shock can kill

OM-4429 Page 408-3. Optional Generator Power Receptacles21 120 V 20 A AC GFCI Receptacle GFCI12 240 V 16 A AC EuropeanReceptacle RC13 240 V 15 A AC Au

Page 40

OM-4429 Page 41SECTION 9 − MAINTENANCE & TROUBLESHOOTING9-1. Maintenance Label

Page 41

OM-4429 Page 429-2. Routine Maintenance! Stop engine before maintaining. See Engine Manual and Maintenance Labelfor important start-up, service, and

Page 42 -  Generator power is not af

OM-4429 Page 439-3. Servicing Air Cleaner! Stop engine.NOTICE − Do not run engine without aircleaner or with dirty element. Enginedamage caused by usi

Page 43 -  Supplementary protector CB7

OM-4429 Page 449-4. Inspecting And Cleaning Optional Spark Arrestor Muffler803 656 / Ref. 215 158! Stop engine and let cool.1 Spark Arrestor Muffler2

Page 44

OM-4429 Page 459-6. Servicing Fuel And Lubrication Systems802 490 / Ref. 801 434! Stop engine and let cool.! After servicing, start engineand check fo

Page 45 - 9-1. Maintenance Label

OM-4429 Page 1SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USINGrom_2007−04Protect yourself and others from injury — read and follow these precautions

Page 46 - 9-2. Routine Maintenance

OM-4429 Page 469-7. Overload Protection803 605219874! Stop engine. When a supplementary protector,circuit breaker or fuse opens, it usu-ally indicate

Page 47 - 9-3. Servicing Air Cleaner

OM-4429 Page 479-8. TroubleshootingA. Welding − CC ModelsTrouble RemedyNo weld output; generator power outputokay at ac receptacles.Check position of

Page 48 - ! Stop engine and let cool

OM-4429 Page 48B. Welding − CC/CV ModelsTrouble RemedyNo weld output; generator power outputokay at ac receptacles.Place Process/Contactor switch in a

Page 49

OM-4429 Page 49Trouble RemedyCheck and secure connections to Remote 14 receptacle RC14 (see Section 5-11).Repair or replace wire feeder.Low CV weld ou

Page 50 - 9-7. Overload Protection

OM-4429 Page 50Trouble RemedyCheck engine wiring harness plug connections.Have Factory Authorized Service Agent check control relay CR1, diode/capacit

Page 51 - 9-8. Troubleshooting

OM-4429 Page 51NotesOver 80,000 trainedsince 1930!400 Trade Square East, Troy, Ohio 453731-800-332-9448 www.welding.orgStart Your ProfessionalWelding

Page 52 - B. Welding − CC/CV Models

OM-4429 Page 52SECTION 10 − ELECTRICAL DIAGRAMSFigure 10-1. Circuit Diagram For CC Welding Generator

Page 53 - E. Engine

OM-4429 Page 53223 525-B

Page 54 - Trouble Remedy

OM-4429 Page 54Figure 10-2. Circuit Diagram For CC/CV Welding Generator

Page 55

OM-4429 Page 55223 524-B

Page 56 - OM-4429 Page 52

OM-4429 Page 2Welding produces fumes and gases. Breathing thesefumes and gases can be hazardous to your health.FUMES AND GASES can be hazardous. Keep

Page 57 - OM-4429 Page 53

OM-4429 Page 56SECTION 11 − RUN-IN PROCEDURErun_in1 2007−0411-1. Wetstacking1 Welding GeneratorRun diesel engines near rated volt-age and current duri

Page 58 - OM-4429 Page 54

OM-4429 Page 5711-2. Run-In Procedure Using Load BankS-06831 Load BankTurn all load bank switches Off. Ifneeded, connect load bank to 115volts ac wall

Page 59 - OM-4429 Page 55

OM-4429 Page 5811-3. Run-In Procedure Using Resistance GridS-06841 Resistance GridUse grid sized for generator ratedoutput.Turn Off grid.2 Welding Gen

Page 60 - SECTION 11 − RUN-IN PROCEDURE

OM-4429 Page 59SECTION 12 − GENERATOR POWER GUIDELINES The views in this section are intended to be representative of all engine-driven welding gener

Page 61

OM-4429 Page 6012-3. Grounding When Supplying Building SystemsST-800 576-B1 Equipment GroundingTerminal2 Grounding CableUse #10 AWG or larger insulate

Page 62

OM-4429 Page 6112-5. Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running WattsSplit Phase 1/8 HP 800 3

Page 63 -  Electrically bond generator

OM-4429 Page 6212-7. Approximate Power Requirements For Contractor EquipmentContractor Rating Starting Watts Running WattsHand Drill 1/4 in 350 3503/8

Page 64 - ! Also see AWS Safety &

OM-4429 Page 6312-8. Power Required To Start MotorSingle-Phase Induction Motor Starting RequirementsMotor StartCodeG H J K L M N PKVA/HP 6.3 7.1 8.0

Page 65

OM-4429 Page 6412-10. Typical Connections To Supply Standby PowerTransfer SwitchEssentialLoadsFusedDisconnectSwitch(If Required) UtilityElectricalServ

Page 66

OM-4429 Page 6512-11. Selecting Extension Cord (Use Shortest Cord Possible)Cord Lengths for 120 Volt LoadsIf unit does not have GFCI receptacles, use

Page 67 - Ref. ST-800 396-A / S-0625

OM-4429 Page 31-3. Engine HazardsBATTERY EXPLOSION can BLIND. Always wear a face shield, rubber gloves, andprotective clothing when working on a batt

Page 68 -  Customer-supplied equipment

OM-4429 Page 66SECTION 13 − PARTS LIST Hardware is common andnot available unless listed.123457689101213141516171819202122232425261011021031041051001

Page 69

OM-4429 Page 67803 844-B272829303132333435363738394041424344454647484950515253545657585960616263646566676869707172737475767778798081828384858688 (Fig.

Page 70 - SECTION 13 − PARTS LIST

OM-4429 Page 68DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-1. Main AssemblyQuantity1 189 824 Panel, Gen Lh 1. . . . . . . . . . . . . . . . . . . .

Page 71 - 803 844-B

OM-4429 Page 69DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-1. Main Assembly (Continued)Quantity39 216 133 Engine, Perkins Dsl Elec 404C−22T 1. . . .

Page 72 - OM-4429 Page 68

OM-4429 Page 70DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-1. Main Assembly (Continued)Quantity77 190 190 Tank, Coolant Recovery 1. . . . . . . . . .

Page 73 - OM-4429 Page 69

OM-4429 Page 71DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-1. Main Assembly (Continued)Quantity123 212 944 Label, Weld Control/Arc Condition Informati

Page 74

OM-4429 Page 72803 845-D2123543620182116151781171219139101422Figure 13-2. Control Box Assembly − CC Models

Page 75 - OM-4429 Page 71

OM-4429 Page 73DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-2. Control Box Assembly − CC Models (Figure 13-1 Item 111)Quantity1 F1, F2 *085 874 FUSE, m

Page 76 - 803 845-D

OM-4429 Page 74803 846-D22123151917181614138491221201056711Figure 13-3. Control Box Assembly − CC/CV ModelsDescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13

Page 77 - OM-4429 Page 73

OM-4429 Page 75DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-3. Control Box Assembly − CC/CV Models (Continued)Quantity17 134 201 STAND-OFF, support pc

Page 78 - 803 846-D

OM-4429 Page 4HOT METAL from air arc cutting andgouging can cause fire or explosion. Do not cut or gouge near flammables. Watch for fire; keep extin

Page 79 - OM-4429 Page 75

OM-4429 Page 76 Hardware is common andnot available unless listed.803 649123456789111012131415161819202122232425262728293031323433353637383940414217F

Page 80 -  Hardware is common and

OM-4429 Page 77DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-4. Panel, Front w/Components − CC Models (Continued)Quantity3 215 014 PANEL, engine/weld co

Page 81 - OM-4429 Page 77

OM-4429 Page 78 Hardware is common andnot available unless listed.803 6501131143027544253525150464749484439404138373635433429283325655575817681093541

Page 82

OM-4429 Page 79DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-5. Panel, Front w/Components − CC/CV Models (Continued)Quantity12 S2 021 467 SWITCH, tgl sp

Page 83 - OM-4429 Page 79

OM-4429 Page 8055 097 922 KNOB, pointer .875 dia x .250 ID w/set screws plstc 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 84

OM-4429 Page 81DescriptionPartNo.Dia.Mkgs.ItemNo.Figure 13-6. Generator (Continued)Quantity12 210 446 ROTOR, Generator (Includes) 1. . . . . . . . .

Page 85 - OM-4429 Page 81

OM-4429 Page 82 Hardware is common andnot available unless listed.802 279-A123465789Figure 13-7. Main Rectifier AssemblyDescriptionPartNo.Dia.Mkgs.It

Page 86

OM-4429 Page 83 Some wiring harness components (switches, relays, circuit breakers) are also referenced elsewhere in this parts list. Purchase compon

Page 87 - OM-4429 Page 83

OM-4429 Page 84215207 Harness, Unit Weld Control CV (Includes) 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 88 - OM-4429 Page 84

Warranty Questions?Call1-800-4-A-MILLERfor your localMiller distributor.miller_warr 2007−01Your distributor also givesyou ...ServiceYou always get the

Page 89 - Effective January 1, 2007

OM-4429 Page 5H.F. RADIATION can cause interference. High-frequency (H.F.) can interfere with radionavigation, safety services, computers, andcommuni

Page 90 - Owner’s Record

PRINTED IN USA © 2007 Miller Electric Mfg. Co.2007−01Miller Electric Mfg. Co.An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914

Related models: Big Blue 600 X

Comments to this Manuals

No comments