Electric Steam- and Hot Water Boilers Product Catalog 2013 Electra Steam, Inc. R
RX36 – RX120 Steam Boiler Series Steam Outlet (NPT) HEATING POWER kW STEAM
POWER SUPPLY kW V A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL ELEMENT WIRING AWG (mm2) NU
MODEL RX/RXH/RXHC-36 RX/RXH/RXHC-40 RX/RXH/RXHC-45 RX/RXH/RXHC-54 RX/RXH/RXHC-60 RX/RXH/RXHC-72 RX/RXH/RXHC-80 EL in (mm) 0 0 24 (610) 24 (61
MODEL RX/RXH/RXHC-100 RX/RXH/RXHC-120 EL in (mm) 36 (915) 36 (915) ER in (mm) 36 (915) 36 (915) Reimers Electra Steam, Inc. 1/1/2013
Transformer Option Part Number Boiler Model Main Boiler Supply Voltage R- RH- and RHC- 208V OPT101
RHP120 – RHP300 Steam Boiler Series Steam Outlet Size (NPT)Steam Pressure HEATING POWER kW S
POWER SUPPLY HEATING POWER kW VOLTAGE V PH AMP DRAW A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL EL
PRESSURE TRABSDUCER FOR PID-OPERATING PRESSURE CONTROLLER SECONDARY LOW WATER CUT-OFF SENSOR FOR BOI
Reimers Electra Steam, Inc. 1/1/2013 PAGE 16 RHP120 – 300 Brochure Rev. 1 RH
RHP & RHPH210 – 300 MODELS (Approximate Dimensions) RHPHC210 – 300 MODELS (Approximate Dimensio
Table of Content Electric Steam Boilers Steam Boiler Models with Carbon Steel Pressure Vessels Miniature Steam Boiler Models, Maximum Working P
Optional Equipment 1. Timer Controlled Boiler Blowoff System, #OPT1001: 2. Automatic Flush & Drain System, #OPT1016
RHP360 – RHP510 Steam Boiler Series Steam Outlet Size (NPT)Steam Pressure
POWER SUPPLY HEATING POWER kW VOLTAGE V PHASE AMP DRAW A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL ELEM
STEAM OUTLET VALVE: 2” OR 3” (DEPENDING ON BOILER MODEL) NPT BRONZE GLOBE VALVESECONDARY LOW WATER CUT-OFF SENSOR FOR
Dimensional Drawings (approximate) Reimers Electra Steam, Inc. 1/1/2013 PAGE 22 RHP360 – 510 Brochure Rev. 1RHP/RHPH360 – RHP
RHPHC360 – RHPHC510 Reimers Electra Steam, Inc. 1/1/2013 PAGE 23 RHP360 – 510 Brochure Rev. 1
Optional Equipment 1. Timer Controlled Boiler Blowoff System, #OPT1001: 2. Automatic Flush & Drain System, #OPT1016
RHP600 – RHP750 Steam Boiler Series HEATING POWER kW STEAM CAPACITY l
POWER SUPPLY HEATING POWER kW VOLTAGE V PHASE AMP DRAW A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL EL
STEAM OUTLET VALVE: 4” FLANGED CLASS 150# SECONDARY LOW WATER CUT-OFF SENSOR FOR BOILER CONTROLLER AUTOMATIC WATER REFILL &
AR4 - 8 Steam Boiler Series (1) Each boiler model requires two (2) power supplies: Primary
Dimensional Drawings (approximate) RHP/RHPH600 – RHP/RHPH750 Reimers Electra Steam, Inc. 1/1/2013 PAGE 28 RHP600 – 750 Brochure
RHPHC600 – RHPHC750 Reimers Electra Steam, Inc. 1/1/2013 PAGE 29 RHP600 – 750 Brochure Rev. 1
Optional Equipment 1. Timer Controlled Boiler Blowoff System, #OPT1001: 2. Automatic Flush & Drain System, #OPT1016
SR20 Stainless Steel Steam Boiler Series Features • Miniature boiler • Maximum safety valve setting 100psi • Al boilers are manufactured
Construction Electrical Enclosure and Shell Wrapper: 304 Stainless Steel Shell Thermal Insulation: Fiberglass:
Overall Dimensions SR20/SRH20 – Models SRXHC20 – Models Reimers Electra Steam, Inc. 1/1/2013 PAGE 33 SR20 Brochure
Optional Equipment 1. #OPT1016 : Automatic Flush & Drain Pressure Controlled Boiler Blowoff System 2. #OPT1001: Timer Controlled
SR40 – SR120 Steam Boiler Series Steam Outlet (NPT) HEATING POWER kW ST
POWER SUPPLY kW V A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL ELEMENT WIRING AW
MODEL SR/SRH/SRHC-40 SR/SRH/SRHC-60 SR/SRH/SRHC-60 EL in (mm) 0 0 24 (610) ER in (mm) 24 (610) 24 (610) 24 (610) Dimensional Drawings
HEATING POWER kW VOLTAGE V PHASE AMP DRAW A MIN REQUIRED N.E.C. SERVICE A NUMBER & SIZES OF CONTACTORS NUMBER & SIZE O
MODEL SR/SRH/SRHC-120 EL in (mm) 36 (915) ER in (mm) 36 (915) SR120 Model SRH120 Model SRHC120 Model Element Removal Clearance Left &
Boiler Model Stacking Frame SR, SRH, SRHC40-80 20562 SR, SRH, SRHC120 20570 Transformer Option Pa
HLR15 – HLR105 Hot Water Boiler Series Capacity MODEL BTU/H KW NO. OF STEPS VOLTS(1) PHASE IN
POWER SUPPLY kW V A MIN REQ. N.E.C. SERVICE A INTERNAL POWER FUSING INTERNAL ELEMENT WIRING AWG (mm2)NUMBER &
Reimers Electra Steam, Inc. 1/1/2013 PAGE 42 HLR15 – 105 Brochure Rev. 1 Dimensional Drawings (approximate) HLR15 – HLR75
Boiler Main Power Supply Voltage Transformer Option Part Number 208V OPT1010 – 208R 240V O
HLR120 – HLR180 Hot Water Boiler Series Features • Maximum pressure 100psi • Maximum temperature 250°F • All boilers are manufactured i
Construction Electrical Enclosure: 12gage carbon steel black painted Water Outlet: 2-1/2” NPT Shell Wrapper: 16gage carbon steel black pain
Overall Dimensions (approximate) Reimers Electra Steam, Inc. 1/1/2013 PAGE 46 HLR120 - 180 Brochure Rev. 1
Detailed Technical Specifications Boiler Controller - Max. boiler operating temperature: 240.0°F (115.6°C) - One sensor operation – sensor A contr
1. Boiler Power OFF 2. Blowoff Enable Switch ON 3. Steam pressure drops below the setting of the blowoff pressu
HLR210 – HLR510 Hot Water Boiler Series Capacity MODEL BTU/H KW NO. OF
POWER SUPPLY BOILER HEATING POWER kW PRIMARY VOLTAGE V PHASE AMP DRAW A MIN REQ. N.E.C. SERVICE
Reimers Electra Steam, Inc. 1/1/2013 PAGE 50 HLR210 – 510 Brochure Rev. 1 HLR210 – HLR300 HLR360 – HLR510 Dimensional Dra
Transformer Option Part Number Boiler Model Boiler Main Power Supply Voltage HLR210 HLR240 – HLR420
HLR600 – HLR900 Hot Water Boiler Series Capacity MODEL BTU/H KW NO. OF
POWER SUPPLY HEATING POWER kW VOLTAGE V PHASE AMP DRAW A MIN REQ. N.E.C. SERVICE A INTERNAL POW
Reimers Electra Steam, Inc. 1/1/2013 PAGE 54 HLR600 – 900 Brochure Rev. 1 Dimensional Drawings (approximate) HLR600 - 900 M
Boiler Main Power Supply Voltage Transformer Option Part Number 380V OPT1011 - 380RH 415V O
Reimers Electra Steam has been manufacturing electric boilers, electric steam generators and quality steam
RB10 – RB30 Steam Boiler Series Steam Outlet (NPT) HEATING POWER kW ST
POWER SUPPLY kW V A MIN REQU. N.E.C. SERVICE A INTERNAL POWER FUSING NUMBER & SIZES OF CONTACTORS NUM
RB10 – RB30 Models Dimensional Drawings RBH10 – RBH30 Models RBHC10 – RBHC30 Reimers Electra Steam, Inc. 1/1/2013 PAGE 6 RB10 – 30 Brochure
Optional Equipment And Accessories Pressure Controlled Boiler Blowoff System Automatic Flush & Drain (No
Comments to this Manuals