OM-129 647 Page 29
7-3. Servicing Air Cleaner
aircleaner1 4/96 ST-153 929-B / ST-153 585 / Ref. ST-180 933-B / Ref. S-0698-B
Stop engine.
Do not run engine without air
cleaner or with dirty element.
Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.
1 Dust Cap
2 Baffle
3 Element
4 Plastic Fins
5 Housing
To clean air filter:
Wipe off cap and housing. Remove
cap and dump out dust. Wipe dust
from inside cap and housing with
damp cloth. Remove element and
reinstall cap.
Do not clean housing with air
hose.
Clean element with compressed air
only. Keep nozzle at least 1 in (25
mm) from inside of element. Max.
air pressure: 100 psi (690 kPa). Do
not remove plastic fins. Replace
element if it has holes or damaged
gaskets.
Reinstall element and cap (cap
arrows pointing up).
1235 4
Blow Inspect
Page view 32